A-beta, BioLegend, 803001

BioLegend 803001 · A-beta · mAb · Mouse
4.05
(Overall rating from 2 reviews)
#1 of 3 targeting A-beta
4.05
From 2 reviews · #1 of 3 for A-beta

What do reviewers generally think about 803001 from BioLegend?

Researchers report that A-beta, BioLegend, 803001 performs well for detecting amyloid beta in human tissue and hiPSC-derived cerebral organoids. One reviewer points out that it works fine for immunocytochemistry of hiPSC-derived cerebral organoids at 1:2000. Another reviewer used it at 1:500 in 1% BSA/PBS with ice-cold acetone fixation and DAKO EnVision secondary on human postmortem cortex cryosections, finding it worked beautifully and compared favorably with clone 4G8 for amyloid beta deposition. No complaints are mentioned.

Information about this antibody

Target
Alt. Targets
Vendor
Catalog No
803001
Clonality
mAb
Origin
Mouse
Reactivity
Human
Conjugation
N/A
Product Link
N/A

Vendor notes

No vendor notes available for this antibody.

pAbmAbs Average Ratings

ℹ
Immunostaining
4.06
Overall
4.05
Add your own rating

User Reviews (2)

Review of: A-beta, BioLegend, 803001 by Swagata Ghatak, The Scripps Research Institute

Reviewed: May 18, 2020

Works fine for ICC of hiPSC derived cerebral organoids.

Dilution used: 1:2000

For more information see Ghatak et al. eLife 2019, “Mechanisms of hyperexcitability in Alzheimer’s disease hiPSC-derived neurons and cerebral organoids vs. isogenic controls“
https://elifesciences.org/articles/50333v1

Immunostaining

Review of: A-beta, BioLegend, 803001 by Maarten Rotman

Reviewed: December 2, 2015

I used mouse IgG1 anti human Abeta1-16 (Covance, clone 6E10, # SIG-39320 ) to detect amyloid beta depositions. [note: Covance antibodies has now become BioLegend]

Conditions: 1:500 dilution of antibody in 1% BSA in PBS solution, fixative was ice cold acetone, block solution was DAKO peroxidase blocking reagent.

Tissues: human post mortem cryosections of the cortex of healthy controls, and human AD/CAA and human HCHWA-D patients.

Used DAKO EnVision anti mouse polymer-HRP as a secondary ‘antibody’ treatment.

Results: worked beautifully (just as well as m-a-Abeta clone 4G8, a more regularly used antibody for ABeta detection)

For more info see publication 10.1016/j.neuroscience.2011.05.076 or AlzForum post http://www.alzforum.org/antibodies/app-or-v-amyloid-6e10-0