Fibrillarin, Abcam, ab4566
What do reviewers generally think about ab4566 from Abcam?
Researchers report that Fibrillarin, Abcam, ab4566 performs well for immunocytochemistry and Western blotting. One reviewer points out that it works great for ICC on fly testis, ovary, and other tissues at 1:200. Another found it effective at 1:5000 in HEK293 cell extract for verifying FBL knockdown, detecting a 35 kDa band with no unspecific binding and good signal after 5 minutes of exposure. Overall, the consensus is positive for specificity, signal strength, and utility in these applications.
Information about this antibody
Vendor notes
User Reviews (2)
Review of: Fibrillarin, Abcam, ab4566 by Bing Zhang initiative
Works great for ICC on fly testis, ovary and other tissues. Dilution: 1:200
Review of: Fibrillarin, Abcam, ab4566 by Britt Ardal, Aarhus University
FBL (Fibrillarin abcam ab4566)
Used in 1:5000 on HEK293 cell-extract to verify FBL knockdown.
(load of protein: 0.4 Bradford units/10 uL)
Band detected at 35 kDa. No unspecific binding. Good signal after 5 minutes of exposure time to film.