TBK1, Thermo Fisher Scientific, PA5-17478
Information about this antibody
Vendor notes
User Reviews (1)
Review of: TBK1, Thermo Fisher Scientific, PA5-17478 by pAbmAbs Data Mining
Our team has carried out deep research in the published scientific literature to identify papers and reports using antibodies directed against human TBK1 and followed up by extraction and evaluation of the available data to assess its performance according to pAbmAbs rating criteria.
YCharOS is here conducting a large head-to-head study comparing 11commercial research antibodies against human TBK1
The collection of antibodies was tested using U2OS WT and TBK1 KO cells in the applications WB (WT and KO cell lysates/50 µg protein), IP (WT cell lysate) and IF (WT and KO cells) according to YCharOS standard protocols (see reference).
In WB (1:10000 ab dilution) PA5-17478 detected a band of appr. 80 kDa in WT cell lysate with no corresponding band observed in KO cell lysate. No band was detected following IP (1 µg Ab used). In IF (1:1000 ab dilution), WT cells showed slightly more stain compared to KO showing background staining.
We highly encourage other scientists to share their observations.
Comments