Parkin, Thermo Fisher Scientific, MA5-41212
Information about this antibody
Vendor notes
User Reviews (1)
Review of: Parkin, Thermo Fisher Scientific, MA5-41212 by pAbmAbs Data Mining
Our team has carried out deep research in the published scientific literature to identify papers and reports using antibodies directed against human E3 ubiquitin-protein ligase parkin and followed up by extraction and evaluation of the available data to assess its performance according to pAbmAbs rating criteria.
YCharOS is here conducting a large head-to-head study comparing 16 commercial research antibodies against human E3 ubiquitin-protein ligase parkin encoded by PRKN.
The collection of antibodies was tested using SH-SY5Y WT and PRKN KO cells in the applications WB (WT and KO cell lysates/50 µg protein), IP (WT cell lysate) and IF (WT and KO cells) according to YCharOS standard protocols (see reference).
This antibody was not tested in IF.
In WB (unknown dilution) MA5-41212, detected bands of appr. 50 kDa and 120 kDa in both genotypes. Only antibodies that depleted the antigen from the cell lysate were used for IP; this antibody did not deplete the antigen. In IF (unknown dilution)
Comments