Caveolin-1, Thermo Fisher Scientific, MA3-600
Information about this antibody
Vendor notes
User Reviews (1)
Review of: Caveolin-1, Thermo Fisher Scientific, MA3-600 by pAbmAbs Data Mining
Our team has carried out deep research in the published scientific literature to identify papers and reports using antibodies directed against human Caveolin-1 and followed up by extraction and evaluation of the available data to assess its performance according to pAbmAbs rating criteria.
YCharOS is here conducting a large head-to-head study comparing 17 commercial research antibodies against human Caveolin-1 encoded by CAV1
The collection of antibodies was tested using U-87 MG and CAV1 KO cells in the application WB (WT and KO cell lysates/20 µg protein), according to YCharOS standard protocols (see reference).
In WB (1:500) MA3-600 detected a faint band of appr. 20 kDa in WT lysate, with no corresponding band observed in KO lysate. A band of higher molecular weight was observed in both genotypes.
We highly encourage other scientists to share their observations.
Comments